MS4000 SeriesMP4000
Rack Mount Type
Blank Panel








Rack Mount Type
Blank Panel
|
Used to fill unused slots in the RC4000 chassis. No successor model. |
|
500Yen |
45Days
|
3Years |
-
-
|
|
Rack Mount Type
Non-Conditioning I/O Adapter
|
I/O adapter used to connect to the output connectors for RC4100 without any signal conditioning |
|
12,000Yen |
45Days
|
3Years |
-
-
|
|
Rack Mount Type
Thermocouple Temperature Transmitter
|
Accepts millivolt signals from a thermocouple, performs cold junction compensation, amplification and linearization, and provides two mutually isolated DC output signals. |
|
49,000Yen / 69,000Yen |
45Days
|
3Years |
-
-
|
InputThermocouple types: K, E, J, T, B, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others Output 21 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
RTD Temperature Transmitter
|
Supplies constant current to RTD, performs cold junction compensation, amplification and linearization of its millivolt input signals, and provides two mutually isolated DC output signals. |
|
48,000Yen / 68,000Yen |
45Days
|
3Years |
-
-
|
InputRTD: Pt 100Ω, JPt 100Ω, Ni 508.4Ω, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others Output 21 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
Millivolt Isolator
|
Amplifies millivolt signals from sensors or other devices and converts them into two mutually isolated DC output signals. |
|
45,000Yen / 65,000Yen |
45Days
|
3Years |
-
-
|
InputmV DC voltage (5 to 200mV DC span) Output 14 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others Output 21 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
High-Level Signal Conditioner (Isolator)
|
Converts high-level DC input signals into two mutually isolated DC output signals. |
|
40,000Yen / 60,000Yen |
45Days
|
3Years |
-
-
|
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Output 21 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
Alarm Setter (Alarm Unit)
|
Compares the levels of DC current or voltage signals with two set-points and outputs two independent isolated relay contact closure signals. |
|
50,000Yen |
45Days
|
3Years |
-
-
|
Input4 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others Output 1Relay contacts Output 2Relay contacts Response TimeApprox. 3ms |
Rack Mount Type
Distributor
|
Powers a two-wire transmitter and converts its 4 to 20mA signals into two mutually isolated DC output signals. |
|
50,000Yen / 70,000Yen |
45Days
|
3Years |
-
-
|
Input4 to 20mA Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Output 21 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
Pulse Shaper
|
Amplifies pulse input signals, shapes these pulses, and converts them into two mutually isolated pulse output signals. |
|
50,000Yen / 70,000Yen |
45Days
|
3Years |
-
-
|
InputDry contact, open collector, DC voltage pulse, AC voltage pulse Output 1TTL, open collector, voltage pulse Output 2TTL, open collector, voltage pulse |
Rack Mount Type
Potentiometer Transmitter
|
Supplies constant current to potentiometric sensors, amplifies the millivolt signals, and converts them into two mutually isolated DC output signals. |
|
55,000Yen / 75,000Yen |
45Days
|
3Years |
-
-
|
InputSpecify between 0-100Ω and 0-10kΩ from 3-wire potentiometer Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Output 21 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
High-Level Signal Conditioner for Output
|
Converts high-level DC input signals into two mutually isolated DC output signals. |
|
45,000Yen / 65,000Yen |
45Days
|
3Years |
-
-
|
Input1 to 5V, 0 to 5V, 0 to 10V Output 11 to 5V, 0 to 5V, 0 to 10V, 4 to 20mA Output 21 to 5V, 0 to 5V, 0 to 10V Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
Alarm Setter (Alarm Unit) for 2-Wire Transmitter
|
Powers a two-wire transmitter, compares its 4 to 20mA signals with two set-points and outputs two independent isolated relay contact closure signals. |
|
50,000Yen |
45Days
|
3Years |
-
-
|
Input4 to 20mA Output 1Relay contacts Output 2Relay contacts Response TimeApprox. 3ms |
Rack Mount Type
AC Power Supply Unit
|
Accepts commercial AC power and provides 24V DC power for the MS4100 series signal conditioners. |
|
25,000Yen |
45Days
|
3Years |
-
-
|
Input100V AC, 110V AC, 115V AC, 200V AC, 220V AC, 240V AC Output 124V DC |
Rack Mount Type
Rack
|
Rack for the MS4100 series signal conditioners |
|
27,000Yen |
45Days
|
3Years |
-
-
|
|
Rack Mount Type
Rack
|
Rack for the MS4100 series signal conditioners |
|
29,000Yen |
45Days
|
3Years |
-
-
|
|
Rack Mount Type
Rack
|
Rack for the MS4100 series signal conditioners |
|
32,000Yen |
45Days
|
3Years |
-
-
|
|
Rack Mount Type
Rack
|
Rack for the MS4100 series signal conditioners |
|
34,000Yen |
45Days
|
3Years |
-
-
|
|
Rack Mount Type
I/O Cable
|
Cable assembly for the RC4100 I/O connectors |
|
|
45Days
|
3Years |
-
-
|
|
Rack Mount Type
Blank Panel
|
Used to fill unused slots in the RC4100 chassis. |
|
500Yen |
45Days
|
3Years |
-
-
|
|
Rack Mount Type
2-Wire RTD Temperature Transmitter
|
Supplies constant current to 3-wire RTD, performs cold junction compensation, amplification and linearization of its millivolt input signals, and provides two-wire DC current signals (4 to 20mA) for standard DC drive. |
|
68,000Yen |
45Days
|
3Years |
-
-
|
InputRTD: Pt 100Ω, JPt 100Ω, Ni 508.4Ω, and others Output 14 to 20mA Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
2-Wire Millivolt Isolator
|
Amplifies millivolt signals from sensors or other devices and converts them into 4 to 20mA output signals. |
|
40,000Yen |
45Days
|
3Years |
-
-
|
InputmV DC voltage (3 to 200mV DC span) Output 14 to 20mA Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
2-Wire Pneumatic-Electric Converter
|
Measures a pneumatic signal with a semiconductor pressure transducer and converts it into 4 to 20mA output signals. |
|
70,000Yen |
45Days
|
3Years |
-
-
|
Input19.6 to 98.1KPa, 19.6 to 176.6KPa, 20 to 100KPa, 3 to 27psiG, 3 to 15psiG, and others Output 14 to 20mA Response TimeApprox. 25ms (0 to 99%) |
Rack Mount Type
Non-Conditioning I/O Adapter
|
I/O adapter used to connect to the output connectors for RC2300 without any signal conditioning. Successor model:MS4100-TB |
|
12,000Yen |
45Days
|
3Years |
-
-
|
|
Rack Mount Type
Thermocouple Temperature Transmitter
|
Accepts millivolt signals from a thermocouple, performs cold junction compensation, amplification and linearization, and provides DC output signals. Successor model: MS3701 or MS4101 |
|
59,000Yen |
45Days
|
3Years |
-
-
|
InputThermocouple types: K, E, J, T, B, and others Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
RTD Temperature Transmitter
|
Supplies constant current to RTD, performs cold junction compensation, amplification and linearization of its millivolt input signals, and provides DC output signals. Successor model:MS3702 or MS4102 |
|
58,000Yen |
45Days
|
3Years |
-
-
|
InputRTD: Pt 100Ω, JPt 100Ω, Ni 508.4Ω, and others Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
Millivolt Isolator
|
Amplifies millivolt signals from sensors or other devices and converts them into commonly used DC signals. Successor model: MS3703 or MS4103 |
|
55,000Yen |
45Days
|
3Years |
-
-
|
InputmV DC voltage (5 to 200mV DC span) Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
High-Level Signal Conditioner (Isolator)
|
Converts high-level DC input signals into DC output signals. Successor model: MS3704 or MS4104 |
|
50,000Yen |
45Days
|
3Years |
-
-
|
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
Alarm Setter (Alarm Unit)
|
Compares the levels of DC current or voltage signals with two set-points and outputs two independent isolated relay contact closure signals. Successor model: MS3705 or MS4105 |
|
50,000Yen |
45Days
|
3Years |
-
-
|
Input1 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Output 1Relay contacts Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
Strain Gauge Transmitter
|
Supplies excitation voltage to strain-gauge type pressure sensors, load cells and the like, amplifies the millivolt input signals, and converts them into DC output signals. Successor model: MS3706 |
|
55,000Yen |
45Days
|
3Years |
-
-
|
Input0 to 10mV, 0 to 100mV, +/-10mV, +/-100mV, and others Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
Distributor
|
Powers a two-wire transmitter and converts its 4 to 20mA signals into commonly used DC signals. Successor model: MS3707 or MS4107 |
|
55,000Yen |
45Days
|
3Years |
-
-
|
Input4 to 20mA Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |