Power Transducer:Sensor Signal Conditioners:PT Transmitters
MS4400 SeriesMS4421
Front Terminal Connection Type
AC Voltage Transducer
Calculates the rms values of AC current signals from a PT and converts them into commonly used DC signals.
25,000Yen
7Days
1Years
-
-
Input
0 to 150V AC, 0 to 300V AC, and others
Output 1
4 to 20mA, 0 to 1mA, 1 to 5V, 0 to 5V, 0 to 10V, and others
Response Time
500ms max.
Power Transducer:Power Transducers:Power Transducers
MS4400 SeriesMS4431
Front Terminal Connection Type
Power Transducer
Accepts the power consumption of power equipment via current and potential transformers and converts it into commonly used DC signals.
50,000Yen
/
67,000Yen
7Days
1Years
-
-
Input
110V AC 5A / 1A, 220V AC 5A / 1A, and others
Output 1
4 to 20mA, 0 to 1mA, 1 to 5V, 0 to 10V, 4 to 12 to 20mA, -1 to 0 to +1mA, 1 to 3 to 5V, -10 to 0 to +10V, and others
Response Time
500ms max.
Power Transducer:Power Transducers:Reactive Power Transducers
MS4400 SeriesMS4432
Front Terminal Connection Type
Reactive Power Transducer
Measures the reactive power of power equipment from AC signals input via current and potential transformers and converts it into commonly used DC signals.
54,000Yen
/
71,000Yen
7Days
1Years
-
-
Input
10V AC 5A / 1A, 220V AC 5A / 1A, and others
Output 1
4 to 20mA, 0 to 1mA, 1 to 5V, 0 to 10V, 4 to 12 to 20mA, -1 to 0 to +1mA, 1 to 3 to 5V, -10 to 0 to +10V, and others
Response Time
500ms max.
Power Transducer:Power Transducers:Power Factor Transducer
MS4400 SeriesMS4434
Front Terminal Connection Type
Power Factor Transducer
Measures the power factor of load from AC signals input via current and potential transformers and converts it into commonly used DC signals.
65,000Yen
/
95,000Yen
7Days
1Years
-
-
Input
110V AC 5A / 1A, 220V AC 5A / 1A
Output 1
4 to 20mA, -1 to 1mA, 1 to 5V, -5 to 5V, -10 to +10V, and others
Response Time
1sec max.
Power Transducer:Power Transducers:Frequency Transducers
MS4400 SeriesMS4435
Front Terminal Connection Type
Frequency Transducer
Accepts power frequency via a potential transformer and converts it into commonly used DC signals.
34,000Yen
7Days
1Years
-
-
Input
45 to 54Hz, 45 to 55Hz, 55 to 65Hz
Output 1
4 to 20mA, 0 to 1mA, 1 to 5V, 0 to 5V, 0 to 10, and others
Response Time
1sec max.
Power Transducer:Power Transducers:Phase Angle Transducer
MS4400 SeriesMS4441
Front Terminal Connection Type
Phase Angle Transducer
Measures phase angle from AC signals input via current and potential transformers and converts it into commonly used DC signals.
50,000Yen
/
65,000Yen
7Days
1Years
-
-
Input
110V AC 5A / 1A, 220V AC 5A / 1A
Output 1
4 to 20mA, -1 to 1mA, 1 to 5V, -5 to 5V, -10 to +10V, and others