MS5000 SeriesMS5000TH
Unit Type
Non-Conditioning I/O Adapter
Unit Type
Non-Conditioning I/O Adapter
I/O adapter that does not provide any signal conditioning. Units can be ordered with a single or dual circuit, with or without a shunt resistor (250Ω), and with or without an input selector. |
15,000Yen |
Please contact us
|
7Years |
-
RoHS10
|
InputOutput 1Dependent on input signal and input resistance. |
Unit Type
Thermocouple Temperature Transmitter
Converts thermocouple inputs into commonly used DC signals. |
30,000Yen |
Please contact us
|
7Years |
-
RoHS10
|
InputThermocouple types: K, E, J, T, B, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time160ms max. |
Unit Type
RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
30,000Yen |
Please contact us
|
7Years |
-
RoHS10
|
InputRTD: Pt 100Ω, JPt 100Ω, Ni 508.4Ω, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time170ms max. |
Unit Type
Millivolt Isolator
Converts millivolt signals from sensors or other devices into commonly used DC signals. |
30,000Yen |
Please contact us
|
7Years |
-
RoHS10
|
Input0 to 10mV, 0 to 100mV, +/-10mV, +/-100mV, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time160ms max. |
Unit Type
High-Level Signal Conditioner
Converts DC current or voltage signals into commonly used DC signals. |
25,000Yen |
Please contact us
|
7Years |
-
RoHS10
|
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time85ms max. |
Unit Type
Distributor
Powers a two-wire transmitter and converts its 4 to 20mA signals into commonly used DC signals. This model can also be used as an isolator. |
22,000Yen |
Please contact us
|
7Years |
-
RoHS10
|
Input4 to 20mA from 2-wire transmitters (Transmitter power supply: 24V DC) Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time85ms max./150µs max. |
Unit Type
Power Bridge for Power Supply
DIN rail bus connector for potential bridging of devices arranged next to one another across all modules. |
1,200Yen |
Please contact us
|
7Years |
-
RoHS10
|
Nominal Current8A |
Unit Type
Power Bridge for AC Power Supply Unit
DIN rail connector for DIN rail mounting. Universal for TBUS housing. Gold-plated contacts, 5-pos. |
2,500Yen |
Please contact us
|
7Years |
-
RoHS10
|
Nominal Current8A |
Unit Type
Power Bridge Connector
These are connectors used for power bridges to supply power to signal conditioners without using an AC power supply unit nor a DC power terminal block. The MC 1,5/ 5-ST-3,81 GY7035 AU is for right side connection. |
500Yen |
Please contact us
|
7Years |
-
RoHS10
|
Nominal Current8A Connectionright side connection. |
Unit Type
Power Bridge Connector
These are connectors used for power bridges to supply power to signal conditioners without using an AC power supply unit nor a DC power terminal block. The IMC 1,5/ 5-ST-3,81 GY7035 AU is for left side connection. |
500Yen |
Please contact us
|
7Years |
-
RoHS10
|
Nominal Current8A Connectionleft side connection. |
Unit Type
AC Power Supply Unit
This is an AC power supply unit for supplying power to signal conditioners via power bridges. The unit requires special power bridges for AC power supply units (ME 17,5 TBUS 1,5/5-ST-3,81). |
46,000Yen |
Please contact us
|
7Years |
-
RoHS10
|
Rated Input Range100V AC to 240V AC Rated Output Voltage24V DC±1% |
Unit Type
DC Power Terminal Block
This is a DC power terminal block for supplying power to signal conditioners via power bridges. Two separate voltage inputs allow a redundant voltage supply of 24V DC. |
16,000Yen |
Please contact us
|
7Years |
-
RoHS10
|
Input Voltage Range22.4V DC to 27.2V DC Output VoltageInput voltage - 0.8V |
Unit Type
4-Channel Isolator
4-channel I/O isolator, providing full isolation between inputs, outputs, input and output, and I/O and power. |
|
120,000Yen |
Please contact us
|
1Years |
-
-
|
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others |
Unit Type
4-Channel Isolator
4-channel I/O isolator, providing full isolation between inputs, outputs, input and output, and I/O and power. |
|
120,000Yen |
Please contact us
|
1Years |
-
-
|
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others |
Unit Type
Isolator
High power isolator providing a maximum output of +/-10V (output load of +/-300mA) |
|
150,000Yen |
Please contact us
|
Please contact us |
-
-
|
Input0 to 10V, 0 to 5V, +/-10V, +/-5V Output 10 to 10V, 0 to 5V, +/-10V, +/-5V Response Time1s max. |
Unit Type
Switch Box
Switch box with a power fuse |
|
45,000Yen / 90,000Yen |
Please contact us
|
Please contact us |
-
RoHS6
|
InputNumber of channels: 5 or 10 Output 1Fuse rating: 0.5A, 1.3A, 2.0A, 3.0A |
Unit Type
Thermocouple Temperature Transmitter
Accepts millivolt signals from a thermocouple, performs cold junction compensation, amplification and linearization, and provides DC output signals. |
|
62,000Yen |
45Days
|
3Years |
-
-
|
InputThermocouple types: K, E, J, T, B, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Unit Type
RTD Temperature Transmitter
Supplies constant current to RTD, performs cold junction compensation, amplification and linearization of its millivolt input signals, and provides DC output signals. |
|
61,000Yen |
45Days
|
3Years |
-
-
|
InputRTD: Pt 100Ω, JPt 100Ω, Ni 508.4Ω, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Unit Type
Millivolt Isolator
Converts millivolt signals from sensors or other devices into commonly used DC signals. |
|
58,000Yen |
45Days
|
3Years |
-
-
|
InputmV DC voltage (3 to 200mV DC span) Output 14 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Unit Type
High-Level Signal Conditioner (Isolator)
Converts high-level DC input signals into DC output signals. |
|
53,000Yen |
45Days
|
3Years |
-
-
|
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Unit Type
High-Level Signal Conditioner (Isolator) with Isolated Dual Output
Converts high-level DC input signals into two mutually isolated DC output signals. |
|
73,000Yen |
45Days
|
3Years |
-
-
|
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others Output 21 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Unit Type
Alarm Setter (Alarm Unit)
Compares the levels of DC current or voltage signals with two set-points and outputs two independent isolated relay contact closure signals. |
|
58,000Yen |
45Days
|
3Years |
-
-
|
Input4 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others Output 1Relay contacts Output 2Relay contacts Response TimeApprox. 3ms |
Unit Type
Distributor
Powers a two-wire transmitter and converts its 4 to 20mA signals into one mutually isolated DC output signals. |
|
63,000Yen |
45Days
|
3Years |
-
-
|
Input4 to 20mA Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Unit Type
Distributor with Isolated Dual Output
Powers a two-wire transmitter and converts its 4 to 20mA signals into two mutually isolated DC output signals. |
|
83,000Yen |
45Days
|
3Years |
-
-
|
Input4 to 20mA Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Output 21 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Unit Type
Frequency/Analog Converter
Converts pulse train signals from flow meters and the like into commonly used DC signals. |
|
58,000Yen |
45Days
|
3Years |
-
-
|
InputDry contact, open collector, DC voltage pulse, AC voltage pulse Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeDependent on input frequency. |
Unit Type
Pulse Shaper
Amplifies pulse input signals, shapes these pulses, and converts them into two mutually isolated pulse output signals. |
|
58,000Yen |
45Days
|
3Years |
-
-
|
InputDry contact, open collector, DC voltage pulse, AC voltage pulse Output 1TTL, open collector, voltage pulse |
Unit Type
Potentiometer Transmitter
Supplies constant current to potentiometric sensors, amplifies the millivolt signals, and converts them into two mutually isolated DC output signals. |
|
61,000Yen |
45Days
|
3Years |
-
-
|
InputSpecify between 0-100Ω and 0-10kΩ from 3-wire potentiometer. Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Unit Type
Square-Root Extractor
Extracts the square roots of high-level DC input signals and converts them into two mutually isolated DC output signals. |
|
63,000Yen |
45Days
|
3Years |
-
-
|
Input4 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Unit Type
CT Transmitter (Rms Calculation)
Measures the supply voltage of power equipment and converts it into two mutually isolated DC output signals. |
|
55,000Yen |
45Days
|
3Years |
-
-
|
Input0 to 1A AC, 0 to 5A AC, and others Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 40ms (0 to 63%) |
Unit Type
PT Transmitter (Rms Calculation)
Measures the supply voltage of power equipment and converts it into two mutually isolated DC output signals. |
|
55,000Yen |
45Days
|
3Years |
-
-
|
Input0 to 110V AC, 0 to 150V AC, 0 to 300V AC, and others Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 40ms (0 to 63%) |