Power Transducer:Power Transducers:Power Transducers
MS4400 SeriesMS4431
Front Terminal Connection Type
Power Transducer
Accepts the power consumption of power equipment via current and potential transformers and converts it into commonly used DC signals.
50,000Yen
/
67,000Yen
7Days
1Years
-
-
Input
110V AC 5A / 1A, 220V AC 5A / 1A, and others
Output 1
4 to 20mA, 0 to 1mA, 1 to 5V, 0 to 10V, 4 to 12 to 20mA, -1 to 0 to +1mA, 1 to 3 to 5V, -10 to 0 to +10V, and others
Response Time
500ms max.
Power Transducer:Power Transducers:Reactive Power Transducers
MS4400 SeriesMS4432
Front Terminal Connection Type
Reactive Power Transducer
Measures the reactive power of power equipment from AC signals input via current and potential transformers and converts it into commonly used DC signals.
54,000Yen
/
71,000Yen
7Days
1Years
-
-
Input
10V AC 5A / 1A, 220V AC 5A / 1A, and others
Output 1
4 to 20mA, 0 to 1mA, 1 to 5V, 0 to 10V, 4 to 12 to 20mA, -1 to 0 to +1mA, 1 to 3 to 5V, -10 to 0 to +10V, and others
Response Time
500ms max.
Power Transducer:Power Transducers:Power Factor Transducer
MS4400 SeriesMS4434
Front Terminal Connection Type
Power Factor Transducer
Measures the power factor of load from AC signals input via current and potential transformers and converts it into commonly used DC signals.
65,000Yen
/
95,000Yen
7Days
1Years
-
-
Input
110V AC 5A / 1A, 220V AC 5A / 1A
Output 1
4 to 20mA, -1 to 1mA, 1 to 5V, -5 to 5V, -10 to +10V, and others
Response Time
1sec max.
Power Transducer:Power Transducers:Frequency Transducers
MS4400 SeriesMS4435
Front Terminal Connection Type
Frequency Transducer
Accepts power frequency via a potential transformer and converts it into commonly used DC signals.
34,000Yen
7Days
1Years
-
-
Input
45 to 54Hz, 45 to 55Hz, 55 to 65Hz
Output 1
4 to 20mA, 0 to 1mA, 1 to 5V, 0 to 5V, 0 to 10, and others
Response Time
1sec max.
Power Transducer:Power Transducers:Phase Angle Transducer
MS4400 SeriesMS4441
Front Terminal Connection Type
Phase Angle Transducer
Measures phase angle from AC signals input via current and potential transformers and converts it into commonly used DC signals.
50,000Yen
/
65,000Yen
7Days
1Years
-
-
Input
110V AC 5A / 1A, 220V AC 5A / 1A
Output 1
4 to 20mA, -1 to 1mA, 1 to 5V, -5 to 5V, -10 to +10V, and others
Response Time
1sec max.
Power Transducer:Power Transducers:CT Transducers
MS3400 SeriesMS3422
Plug-in Type
CT Transmitter (Rms Calculation, 3 Phase, 3-Wire)
Accepts the supply voltage of power equipment via a potential transformer and converts it into standard process signals.*Last orders received in December 2022
60,000Yen
7Days
1Years
-
-
Input
0 to1A AC, 0 to 5A AC, and others
Output 1
4 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others
Response Time
0.5s max. (90% step input)
Power Transducer:Power Transducers:PT Transducers
MS3400 SeriesMS3423
Plug-in Type
PT Transmitter (Rms Calculation, 3 Phase, 3-Wire)
Accepts the supply voltage of power equipment via a potential transformer and converts it into standard process signals.*Last orders received in December 2022
62,000Yen
7Days
1Years
-
-
Input
0 to 150V AC, 0 to 300V AC, and others
Output 1
4 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others
Response Time
0.5s max. (90% step input)
Power Transducer:Power Transducers:Power Transducers
MS3400 SeriesMS3431
Plug-in Type
Power Transducer
Accepts the power consumption of power equipment via current and potential transformers and converts it into standard process signals.
75,500Yen
7Days
1Years
-
-
Input
Output 1
4 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others
Response Time
1s max. (90% step input)
Power Transducer:Power Transducers:Reactive Power Transducers
MS3400 SeriesMS3432
Plug-in Type
Reactive Power Transducer
Measures the reactive power of power equipment from AC signals input via current and potential transformers and converts it into standard process signals.
73,700Yen
7Days
1Years
-
-
Input
Output 1
4 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others
Response Time
1s max. (90% step input)
Power Transducer:Power Transducers:Power Factor Transducer for Unbalanced Loads
MS3400 SeriesMS3433
Plug-in Type
Power Factor Transducer for Unbalanced Loads
Measures the power factor of load from AC signals input via current and potential transformers and converts it into standard process signals.
93,500Yen
7Days
1Years
-
-
Input
Output 1
4 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others
Response Time
1s max. (90% step input)
Power Transducer:Power Transducers:Power Factor Transducer for Balanced Loads
MS3400 SeriesMS3434
Plug-in Type
Power Factor Transducer for Balanced Loads
Measures the power factor of load from AC signals input via current and potential transformers and converts it into standard process signals.
115,500Yen
7Days
1Years
-
-
Input
Output 1
4 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others
Response Time
1s max. (90% step input)
Power Transducer:Power Transducers:Frequency Transducers
MS3400 SeriesMS3435
Plug-in Type
Frequency Transducer
Accepts power frequency via a potential transformer and converts it into standard process signals.
34,000Yen
7Days
1Years
-
-
Input
45 to 54Hz, 45 to 55Hz, 55 to 65Hz
Output 1
4 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others
Response Time
2s max. (90% step input)
Power Transducer:Power Transducers:Power Transducer (with Pulse Output)
MS3400 SeriesMS3436
Plug-in Type
Power Transducer (with Pulse Output)
Accepts the power consumption of power equipment via current and potential transformers and converts it into commonly used DC signals.
120,000Yen
7Days
1Years
-
-
Input
110V/5A AC
Output 1
4 to 20mA, 0 to 1mA, 1 to 5V, 0 to 5V, 0 to 10V, and others