Search by Application
Steel Plant : Monitoring and control
SEARCH
RESULTS
- Isolated Signal Conditioner:Temperature Transmitters:Thermocouple Temperature Transmitters
-
MS3900 SeriesMS3901
Chassis Mount Type
Thermocouple Temperature Transmitter
Converts thermocouple inputs into commonly used DC signals. |
35,000Yen |
6Days
|
7Years |
CE*
* Some variants are not CE compliant. RoHS10
|
InputThermocouple types: K, E, J, T, B, and others Output 11 to 5V, 0 to 5V, 0 to 10V, +/-5V, +/-10V, 4 to 20mA Output 21 to 5V, 0 to 5V, 0 to 10V, +/-5V, +/-10V, 4 to 20mA Response Time160ms max. |
- Isolated Signal Conditioner:Temperature Transmitters:RTD Temperature Transmitters
-
MS3900 SeriesMS3902
Chassis Mount Type
RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
30,000Yen |
6Days
|
7Years |
CE*
* Some variants are not CE compliant. RoHS10
|
InputRTD: Pt 100Ω, JPt 100Ω, Ni 508.4Ω, and others Output 11 to 5V, 0 to 5V, 0 to 10V, +/-5V, +/-10V, 4 to 20mA Output 21 to 5V, 0 to 5V, 0 to 10V, +/-5V, +/-10V, 4 to 20mA Response Time170ms max. |
- Isolated Signal Conditioner:High-level Signal Conditioners:High-level Signal Conditioners (Isolators)
-
MS3900 SeriesMS3903
Chassis Mount Type
Millivolt Isolator
Converts millivolt signals from sensors or other devices into commonly used DC signals. |
25,000Yen |
6Days
|
7Years |
-
RoHS10
|
Input0 to 10mV, 0 to 100mV, +/-10mV, +/-100mV, and others Output 11 to 5V, 0 to 5V, 0 to 10V, +/-5V, +/-10V Output 21 to 5V, 0 to 5V, 0 to 10V, +/-5V, +/-10V, 4 to 20mA Response Time160ms max. |
- Isolated Signal Conditioner:High-level Signal Conditioners:High-level Signal Conditioners (Isolators)
-
MS3900 SeriesMS3904
Chassis Mount Type
High-Level Signal Conditioner (Isolator)
Converts DC current or voltage signals into commonly used DC signals. |
20,000Yen |
6Days
|
7Years |
CE*
* Some variants are not CE compliant. RoHS10
|
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 11 to 5V, 0 to 5V, 0 to 10V, +/-5V, +/-10V, 1 to 5V, 4 to 20mA Output 21 to 5V, 0 to 5V, 0 to 10V, +/-5V, +/-10V, 4 to 20mA Response Time85ms max. |
- Isolated Signal Conditioner:Distributors:Distributors
-
MS3900 SeriesMS3907
Chassis Mount Type
Distributor
Powers a two-wire transmitter and converts its 4 to 20mA signals into commonly used DC signals. This model can also be used as an isolator. |
25,000Yen |
6Days
|
7Years |
CE*
* Some variants are not CE compliant. RoHS10
|
Input4 to 20mA from 2-wire transmitters (Transmitter power supply: 24V DC) Output 11 to 5V, 4 to 20mA Output 21 to 5V, 4 to 20mA Response Time85ms max. |
- Isolated Signal Conditioner:Sensor Signal Conditioners:Potentiometer Transmitters
-
MS3900 SeriesMS3910
Chassis Mount Type
Potentiometer Transmitter
Detects changes in the resistance of potentiometric sensors and converts them into commonly used DC signals. |
30,000Yen |
6Days
|
7Years |
-
RoHS10
|
InputBetween 0-100Ω and 0-10kΩ Output 11 to 5V, 0 to 5V, 0 to 10V Output 21 to 5V, 0 to 5V, 0 to 10V, 4 to 20mA Response Time170ms max. |
- Isolated Signal Conditioner:Sensor Signal Conditioners:CT Transmitters
-
MS3900 SeriesMS3920
Chassis Mount Type
CT Transmitter (Rms Calculation)
Calculates the rms values of AC current signals from a CT and converts them into commonly used DC signals. |
33,000Yen |
6Days
|
7Years |
-
RoHS10
|
Input0 to 1A AC, 0 to 5A AC, and others Output 11 to 5V, 0 to 5V, 0 to 10V, +/-5V, +/-10V Output 21 to 5V, 0 to 5V, 0 to 10V, +/-5V, +/-10V, 4 to 20mA Response Time400ms max. |
- Isolated Signal Conditioner:Sensor Signal Conditioners:PT Transmitters
-
MS3900 SeriesMS3921
Chassis Mount Type
PT Transmitter (Rms Calculation)
Calculates the rms values of AC current signals from a PT and converts them into commonly used DC signals. |
33,000Yen |
6Days
|
7Years |
-
RoHS10
|
Input0 to 110V AC, 0 to 150V AC, 0 to 300V AC, and others Output 11 to 5V, 0 to 5V, 0 to 10V, +/-5V, +/-10V Output 21 to 5V, 0 to 5V, 0 to 10V, +/-5V, +/-10V, 4 to 20mA Response Time400ms max. |
- Isolated Signal Conditioner:High-level Signal Conditioners:High-level Signal Output Modules
-
MS3900 SeriesMS3954
Chassis Mount Type
High-Level Signal Conditioner
Converts DC current or voltage signals into commonly used DC signals. |
20,000Yen |
6Days
|
7Years |
-
RoHS10
|
Input4 to 20mA, 1 to 5V, 0.4V to 2V, and others Output 14 to 20mA, 550Ω at maximum output for single output Response Time15ms max. |
- Isolated Signal Conditioner:High-level Signal Conditioners:High-level Signal Output Modules
-
MS3900 SeriesMS3954HI
Chassis Mount Type
High-Level Signal Conditioner (High Current Load Model)
Converts DC current or voltage signals into commonly used DC signals. |
20,000Yen |
6Days
|
7Years |
-
RoHS10
|
Input4 to 20mA, 1 to 5V, 0.4V to 2V, and others Output 14 to 20mA, 550Ω at maximum output for single output Response Time15ms max. |
- Isolated Signal Conditioner:Chassis:Chassis for MS3900
-
MS3900 SeriesRC3900A-16AI
Chassis Mount Type
Rack
Chassis for the MS3900 series signal conditioners |
35,000Yen / 50,000Yen |
6Days
|
7Years |
CE
RoHS10
|
InputOutput 1 |
- Isolated Signal Conditioner:Chassis:Chassis for MS3900
-
MS3900 SeriesRC3900A-16AO
Chassis Mount Type
Rack
Chassis for the MS3954 signal conditioners |
35,000Yen / 50,000Yen |
6Days
|
7Years |
-
RoHS10
|
InputOutput 1 |
- Other Products:Other Products:4-channel Isolators
-
MS3900 SeriesMTAA-AI04-00
Isolation Modules (PCB Mount Type)
4-channel Analog Input Add-on Module
Add-on module for Armadillo (made by Atmark Techno). It converts 4 analog DC voltage signals into digital signals and transmits the converted data to Armadillo. |
|
|
Please contact us
|
1Years |
-
RoHS10
|
Input+/-10V DC, +/-5V DC, +/-2.5V DC, 0 to +10V DC, 0 to +5V DC Resolution16 bits (input range is converted into 0 to 65535) Transmission methodSPI communication |
- Remote I/O Systems:I/O Units:For Analog Input
-
CC3900 SeriesCC3901-16AI
Chassis Mount Type
Isolated Signal Conditioning System for 16-Channel Analog Input
CC-Link remote device station (Ver.2 compatible) that Isolates up to 16 channels of analog signal per rack and provides analot-to-digital conversion to transmit digital data to the host. |
|
141,100Yen / 156,100Yen |
Please contact us
|
3Years |
-
RoHS6
|
|
- Remote I/O Systems:I/O Units:For Analog Output
-
CC3900 SeriesCC3901-16AO
Chassis Mount Type
Isolated Signal Conditioning System for 16-Channel Analog Output
CC-Link remote device station (Ver.2 compatible) that converts digital data transmittd from the host into analog data and provides up to 16 channels of analog output signal (channel-to-channel isolation) per rack. |
|
151,100Yen / 166,100Yen |
Please contact us
|
3Years |
-
RoHS6
|
|
- Remote I/O Systems:Remote I/O:Power Units
-
Alchis SeriesMRH-T-PD1
Chassis Mount Type
Power Module (24V DC)
Isolates 24V DC input and supplies 24V DC power to mutiple modules in the same MRH-T system. |
|
20,000Yen |
Please contact us
|
3Years |
-
RoHS6
|
Input24V DC+/-10% Output 12A max. (24V DC @25°C) |
- Remote I/O Systems:Remote I/O:Communication Modules
-
Alchis SeriesMRH-T-NMT1
Chassis Mount Type
Communication Module (Modbus/TCP)
Remote I/O communication module to communicate with the host over Modbus/TCP |
|
65,000Yen |
Please contact us
|
3Years |
-
RoHS6
|
Input- |
- Remote I/O Systems:Remote I/O:Communication Modules
-
Alchis SeriesMRH-T-NCL1
Chassis Mount Type
Communication Module (CC-Link Ver.2)
Remote I/O communication module to communicate with the host over CC-Link (Ver. 2) |
|
65,000Yen |
Please contact us
|
3Years |
-
RoHS6
|
Input- |
- Remote I/O Systems:Remote I/O:I/O Modules
-
Alchis SeriesMRH-T-DI32MS
Chassis Mount Type
Contact Input Module (32 channels)
Isolates 32 contact inputs and transmits the input status to the communication module. |
|
33,000Yen |
Please contact us
|
3Years |
-
RoHS6
|
Input32 digital (contact) inputs (common-by-common isolation) for sinking/sourcing Output 1- Output 2- Response TimeMaximum input frequency: 50Hz (Duty: 40 to 60%) |
- Remote I/O Systems:Remote I/O:I/O Modules
-
Alchis SeriesMRH-T-PI16AMS
Chassis Mount Type
Pulse Accumulation Module (16 channels/ built-in power for input)
Counts 16 pulse inputs and transmits the count value to the communication module. |
|
48,000Yen |
Please contact us
|
3Years |
-
RoHS6
|
Input16 pulse signal inputs (concentrated isolation) for sinking Output 1- Output 2- Response TimeMaximum input frequency: 100Hz (Duty: 50%) |
- Remote I/O Systems:Remote I/O:I/O Modules
-
Alchis SeriesMRH-T-DO32MS
Chassis Mount Type
Contact Output Module (32 channels)
Isolates the digital data transmitted from the communication module and provides a total of 32 contact outputs. |
|
39,000Yen |
Please contact us
|
3Years |
-
RoHS6
|
Input- Output 132 digital (contact) outputs (common-by-common isolation) for sinking Output 2- |
- Remote I/O Systems:Remote I/O:I/O Modules
-
Alchis SeriesMRH-T-ADV16AMS
Chassis Mount Type
DC Voltage Input Module (16 channels)
Converts 16 analog DC voltage inputs into digital signals and transmits the converted data to the communication module. |
|
55,000Yen |
Please contact us
|
3Years |
-
RoHS6
|
Input+/-10V, +/-5V, 0 to 10V, 0 to 5V, 1 to 5V *Configured with configurator Output 1Output 2- Response Time10ms |
- Remote I/O Systems:Remote I/O:I/O Modules
-
Alchis SeriesMRH-T-ADV8DMS
Chassis Mount Type
DC Voltage Input Module (8 channels)
Converts 8 analog DC voltage inputs into digital signals and transmits the converted data to the communication module. |
|
66,000Yen |
Please contact us
|
3Years |
-
RoHS6
|
Input+/-10V, +/-5V, 0 to 10V, 0 to 5V, 1 to 5V, +/-1V, 0 to 1V *Configured with configurator (channel-by-channel isolation) Output 1- Output 2- Response Time10ms |
- Remote I/O Systems:Remote I/O:I/O Modules
-
Alchis SeriesMRH-T-ADV8DS
Chassis Mount Type
DC Voltage Input Module (8 channels)
Converts 8 analog DC voltage inputs into digital signals and transmits the converted data to the communication module. |
|
66,000Yen |
Please contact us
|
3Years |
-
RoHS6
|
Input+/-10V, +/-5V, 0 to 10V, 0 to 5V, 1 to 5V, +/-1V, 0 to 1V *Configured with configurator (channel-by-channel isolation) Output 1- Output 2- Response Time10ms |
- Remote I/O Systems:Remote I/O:I/O Modules
-
Alchis SeriesMRH-T-ADV16AAMS
Chassis Mount Type
DC Voltage Input Module (mV input / 16 channels)
Converts 16 analog DC votalge (millivolt) inputs into digital signals and transmits the converted data to the communication module. |
|
55,000Yen |
Please contact us
|
3Years |
-
RoHS6
|
Input+/-100mV, +/-50mV, 0 to 100mV, 0 to 50mV *Configured with configurator Output 1Output 2- Response Time10ms |
- Remote I/O Systems:Remote I/O:I/O Modules
-
Alchis SeriesMRH-T-ADV8ADMS
Chassis Mount Type
DC Voltage Input Module (mV input / 8 channels)
Converts 8 analog DC voltage inputs into digital signals and transmits the converted data to the communication module. |
|
66,000Yen |
Please contact us
|
3Years |
-
RoHS6
|
Input+/-100mV, +/-50mV, 0 to 100mV, 0 to 50mV *Configured with configurator (channel-by-channel isolation) Output 1Output 2- Response Time10ms |
- Remote I/O Systems:Remote I/O:I/O Modules
-
Alchis SeriesMRH-T-ADV8ADS
Chassis Mount Type
DC Voltage Input Module (mV input / 8 channels)
Converts 8 analog DC voltage inputs into digital signals and transmits the converted data to the communication module. |
|
66,000Yen |
Please contact us
|
3Years |
-
RoHS6
|
Input+/-100mV, +/-50mV, 0 to 100mV, 0 to 50mV *Configured with configurator (channel-by-channel isolation) Output 1- Output 2- Response Time10ms |
- Remote I/O Systems:Remote I/O:I/O Modules
-
Alchis SeriesMRH-T-ADI16AM
Chassis Mount Type
DC Current Input Module (16 channels)
Converts 16 analog DC current inputs into digital signals and transmits the converted data to the communication module. |
|
55,000Yen |
Please contact us
|
3Years |
-
RoHS6
|
Input+/-20mA, 0 to 20mA, 4 to 20mA *Configured with configurator (concentrated isolation) Output 1Output 2- Response Time10ms |
- Remote I/O Systems:Remote I/O:I/O Modules
-
Alchis SeriesMRH-T-ADI16DM
Chassis Mount Type
DC Current Input Module (16 channels)
Converts 16 analog DC current inputs into digital signals and transmits the converted data to the communication module. |
|
84,000Yen |
Please contact us
|
3Years |
-
RoHS6
|
Input+/-20mA, 0 to 20mA, 4 to 20mA *Configured with configurator (channel-by-channel isolation) Output 1Output 2- Response Time10ms |
- Remote I/O Systems:Remote I/O:I/O Modules
-
Alchis SeriesMRH-T-ADI8DM
Chassis Mount Type
DC Current Input Module (8 channels)
Converts 8 analog DC current inputs into digital signals and transmits the converted data to the communication module. |
|
66,000Yen |
Please contact us
|
3Years |
-
RoHS6
|
Input+/-20mA, 0 to 20mA, 4 to 20mA *Configured with configurator (channel-by-channel isolation) Output 1- Output 2- Response Time10ms |
- Overview
- Download
- Price
- Standard Lead Time
- Warranty Period
- Standards & Approvals / RoHS
- Power Supply
- Details
- Basic Information
- Compare