MS5500 SeriesMS5501
Plug-in Type
Thermocouple Temperature Transmitter
Plug-in Type
Thermocouple Temperature Transmitter
Converts thermocouple inputs into commonly used DC signals. |
42,000Yen |
4Days
|
7Years |
-
RoHS10
|
InputThermocouple types: K, E, J, T, B, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time160ms max. |
Plug-in Type
RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
38,000Yen |
4Days
|
7Years |
-
RoHS10
|
InputRTD: Pt 100Ω, JPt 100Ω, Ni 508.4Ω, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time170ms max. |
Plug-in Type
Millivolt Isolator
Converts millivolt signals from sensors or other devices into commonly used DC signals. |
25,000Yen |
4Days
|
7Years |
-
RoHS10
|
Input0 to 10mV, 0 to 100mV, +/-10mV, +/-100mV, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time160ms max. |
Plug-in Type
High-Level Signal Conditioner (Isolator)
Converts DC current or voltage signals into commonly used DC signals. |
25,000Yen |
4Days
|
7Years |
-
RoHS10
|
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time85ms max. |
Plug-in Type
Digital Alarm Setter
Compares the levels of DC current or voltage signals with two set-points (upper and lower limits) and outputs two independent isolated relay contact closure signals. |
50,000Yen |
4Days
|
7Years |
-
RoHS10
|
Input4 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others Output 1Two relay contact outputs; rated load of contact: 2A 125V AC, 2A 30V DC Response Time150ms max. |
Plug-in Type
Strain Gauge Transmitter
Supplies excitation voltage to strain-gauge type pressure sensors, load cells and the like and converts their output signals into commonly used DC signals. |
56,000Yen |
4Days
|
7Years |
-
RoHS10
|
InputSpan: 5 to 400mV; input range: -200 to 200mV; excitation voltage: 5V, 10V DC Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time85ms max. |
Plug-in Type
Distributor (with Isolation)
Powers a two-wire transmitter and converts its 4 to 20mA signals into commonly used DC signals. This model can also be used as an isolator. |
33,000Yen |
4Days
|
7Years |
-
RoHS10
|
Input4 to 20mA from 2-wire transmitters (Transmitter power supply: 24V DC) Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time85ms max. |
Plug-in Type
Frequency/Analog Converter
Converts pulse train signals from flow sensors and the like into commonly used DC signals. |
41,000Yen |
4Days
|
7Years |
-
RoHS10
|
InputOpen collector, DC voltage pulse, current pulse, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response TimeDependent on input frequency. |
Plug-in Type
Potentiometer Transmitter
Detects changes in the resistance of potentiometric sensors and converts them into commonly used DC signals. |
30,000Yen |
4Days
|
7Years |
-
RoHS10
|
InputBetween 0-100Ω and 0-10kΩ Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time170ms max. |
Plug-in Type
Square-Root Extractor
Extracts the square roots of DC current or voltage signals and converts them into commonly used DC signals. |
46,000Yen |
4Days
|
7Years |
-
RoHS10
|
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time120ms max. |
Plug-in Type
CT Transmitter (Rms Calculation)
Calculates the rms values of AC current signals from a CT and converts them into commonly used DC signals. |
35,000Yen |
4Days
|
7Years |
-
RoHS10
|
Input0 to 1A AC, 0 to 5A AC Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time400ms max. |
Plug-in Type
PT Transmitter (Rms Calculation)
Calculates the rms values of AC current signals from a PT and converts them into commonly used DC signals. |
35,000Yen |
4Days
|
7Years |
-
RoHS10
|
Input0 to 110V AC, 0 to 150V AC, 0 to 300V AC, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time400ms max. |
Plug-in Type
Millivolt Isolator (Fast Response Model)
Converts millivolt signals from sensors or other devices into commonly used DC signals. Fast response time: 80μs (0 to 90%) for voltage output, 150μs (0 to 90%) for current output |
38,000Yen |
4Days
|
7Years |
-
RoHS10
|
Input0 to 50mV, 0 to 100mV, +/-50V, +/-100mV, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time80μsec/150μsec max. |
Plug-in Type
High-Level Signal Conditioner (Fast Response Model)
Converts DC current or voltage signals into commonly used DC signals. Fast response time: 80µs (0 to 90%) for voltage output, 150µs (0 to 90%) for current output |
35,000Yen |
4Days
|
7Years |
-
RoHS10
|
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time80µsec/150µsec max. |
Plug-in Type
Universal transmitter (Isolator)
Converts thermocouple、RTD、 DC current or voltage signals into commonly used DC signals. |
|
|
14Days
|
1Years |
-
-
|
InputK、E、J、T、B、R、S、T、PL=Ⅱ、W5Re/W26Re、W3Re・W25R、 Pt 100Ω、JPt 1010Ω 4~20mA 0~20mA 0~10mV 1~5V 0~10V ±10V 0~5V 0~1V Output 14~20mA 1~5V Response Time500ms max. |
Plug-in Type
Universal transmitter (Isolator)
Converts thermocouple、RTD、 DC current or voltage signals into commonly used DC signals. |
|
|
14Days
|
1Years |
-
-
|
InputK、E、J、T、B、R、S、T、PL=Ⅱ、W5Re/W26Re、W3Re・W25R、 Pt 100Ω、JPt 1010Ω 4~20mA 0~20mA 0~10mV 1~5V 0~10V ±10V 0~5V 0~1V Output 14~20mA 1~5V Output 24~20mA 1~5V Response Time500ms max. |
Plug-in Type
Thermocouple Temperature Transmitter
Converts thermocouple inputs into commonly used DC signals. |
|
|
14Days
|
1Years |
-
-
|
InputThermocouple types: K、E、J、T、B、R、S、T、PL=Ⅱ、W5Re/W26Re、W3Re・W25Re Output 14~20mA 1~5V Response Time500ms max. |
Plug-in Type
Thermocouple Temperature Transmitter
Converts thermocouple inputs into commonly used DC signals. |
|
|
14Days
|
1Years |
-
-
|
InputThermocouple types: K、E、J、T、B、R、S、T、PL=Ⅱ、W5Re/W26Re、W3Re・W25Re Output 14~20mA 1~5V Output 24~20mA 1~5V Response Time500ms max. |
Plug-in Type
RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
|
|
14Days
|
1Years |
-
-
|
InputPt 100Ω、JPt 100Ω Output 14~20mA 1~5V Response Time500ms max. |
Plug-in Type
RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
|
|
14Days
|
1Years |
-
-
|
InputPt 100Ω、JPt 100Ω Output 14~20mA 1~5V Output 24~20mA 1~5V Response Time500ms max. |
Plug-in Type
High-Level Signal Conditioner (Isolator)
Converts DC current or voltage signals into commonly used DC signals. |
|
|
14Days
|
1Years |
-
-
|
Input4~20mA 0~20mA 0~10mV 1~5V 0~10V ±10V 0~5V 0~1V Output 14~20mA 1~5V Response Time500ms max. |
Plug-in Type
High-Level Signal Conditioner (Isolator)
Converts DC current or voltage signals into commonly used DC signals. |
|
|
14Days
|
1Years |
-
-
|
Input4~20mA 0~20mA 0~10mV 1~5V 0~10V ±10V 0~5V 0~1V Output 14~20mA 1~5V Output 24~20mA 1~5V Response Time500ms max. |
Plug-in Type
High-Level Signal Conditioner (Isolator)
Converts DC current or voltage signals into commonly used DC signals. |
|
|
14Days
|
1Years |
-
-
|
Input4~20mA 1~5V Output 14~20mA 1~5V Response Time500ms max. |
Plug-in Type
High-Level Signal Conditioner (Isolator)
Converts DC current or voltage signals into commonly used DC signals. |
|
|
14Days
|
1Years |
-
-
|
Input4~20mA 1~5V Output 14~20mA 1~5V Output 24~20mA 1~5V Response Time500ms max. |
Plug-in Type
Digital Alarm Setter
Compares the levels of DC current or voltage signals with two/four set-points (upper and lower limits) and outputs two independent isolated relay contact closure signals. |
|
|
14Days
|
1Years |
-
-
|
Input4~20mA 1~5V OutputTwo form a or b relay contact outputs Response Time500ms max. |
Plug-in Type
Universal Digital Alarm Setter
Converts thermocouple、RTD、 DC current or voltage signals with two/four set-points (upper and lower limits) and outputs two independent isolated relay contact closure signals. |
|
|
14Days
|
1Years |
-
-
|
InputK、E、J、T、B、R、S、T、PL=Ⅱ、W5Re/W26Re、W3Re・W25R、 Pt 100Ω、JPt 1010Ω 4~20mA 0~20mA 0~10mV 1~5V 0~10V ±10V 0~5V 0~1V OutputTwo form a or b relay contact outputs Response Time500ms max. |
Plug-in Type
Distributor (with Isolation)
Powers a two-wire transmitter and converts its 4 to 20mA signals into commonly used DC signals. This model can also be used as an isolator. |
|
|
14Days
|
1Years |
-
-
|
Input4 to 20mA from 2-wire transmitters (Transmitter power supply: 24V DC) Output 14~20mA 1~5V Response Time500ms max. |
Plug-in Type
Distributor (with Isolation)
Powers a two-wire transmitter and converts its 4 to 21mA signals into commonly used DC signals. This model can also be used as an isolator. |
|
|
14Days
|
1Years |
-
-
|
Input4 to 20mA from 2-wire transmitters (Transmitter power supply: 24V DC) Output 14~20mA 1~5V Output 24~20mA 1~5V Response Time500ms max. |
Plug-in Type
Distributor (with Isolation)
Powers a two-wire transmitter and converts its 4 to 21mA signals into commonly used DC signals. This model can also be used as an isolator. |
|
|
14Days
|
1Years |
-
-
|
Input4 to 20mA from 2-wire transmitters (Transmitter power supply: 24V DC) Output 14~20mA 1~5V Response Time500ms max. |
Plug-in Type
Distributor (with Isolation)
Powers a two-wire transmitter and converts its 4 to 22mA signals into commonly used DC signals. This model can also be used as an isolator. |
|
|
14Days
|
1Years |
-
-
|
Input4 to 20mA from 2-wire transmitters (Transmitter power supply: 24V DC) Output 14~20mA 1~5V Output 24~20mA 1~5V Response Time500ms max. |