Search by Application
Hydroelectric Power Generation : Governor control system
SEARCH
RESULTS
- Isolated Signal Conditioner:High-level Signal Conditioners:High-level Signal Conditioners (Isolators)
-
MS3900 SeriesMS3903
Chassis Mount Type
Millivolt Isolator
Converts millivolt signals from sensors or other devices into commonly used DC signals. |
25,000Yen |
6Days
|
7Years |
-
RoHS10
|
Input0 to 10mV, 0 to 100mV, +/-10mV, +/-100mV, and others Output 11 to 5V, 0 to 5V, 0 to 10V, +/-5V, +/-10V Output 21 to 5V, 0 to 5V, 0 to 10V, +/-5V, +/-10V, 4 to 20mA Response Time160ms max. |
- Isolated Signal Conditioner:High-level Signal Conditioners:High-level Signal Conditioners (Isolators)
-
MS3900 SeriesMS3904
Chassis Mount Type
High-Level Signal Conditioner (Isolator)
Converts DC current or voltage signals into commonly used DC signals. |
20,000Yen |
6Days
|
7Years |
CE*
* Some variants are not CE compliant. RoHS10
|
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 11 to 5V, 0 to 5V, 0 to 10V, +/-5V, +/-10V, 1 to 5V, 4 to 20mA Output 21 to 5V, 0 to 5V, 0 to 10V, +/-5V, +/-10V, 4 to 20mA Response Time85ms max. |
- Isolated Signal Conditioner:High-level Signal Conditioners:High-level Signal Conditioners (Isolators)
-
MS3900 SeriesMS3904F
Chassis Mount Type
High-Level Signal Conditioner (High Response Model)
Converts DC current or voltage signals into commonly used DC signals. Fast response: 1kHz-3dB |
25,000Yen |
6Days
|
7Years |
-
RoHS10
|
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 11 to 5V, 0 to 5V, 0 to 10V, +/-5V, +/-10V, 1 to 5V Output 21 to 5V, 0 to 5V, 0 to 10V, +/-5V, +/-10V |
- Isolated Signal Conditioner:Alarm Setters:Alarm Setters
-
MS3900 SeriesMS3905
Chassis Mount Type
Alarm Setter
Compares the levels of DC current or voltage signals with one set-point and outputs two independent isolated relay contact closure signals. |
35,000Yen |
6Days
|
7Years |
-
RoHS10
|
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 1Relay contact output (SPST independent single circuit) Response Time150ms max. |
- Isolated Signal Conditioner:Distributors:Distributors
-
MS3900 SeriesMS3907
Chassis Mount Type
Distributor
Powers a two-wire transmitter and converts its 4 to 20mA signals into commonly used DC signals. This model can also be used as an isolator. |
25,000Yen |
6Days
|
7Years |
CE*
* Some variants are not CE compliant. RoHS10
|
Input4 to 20mA from 2-wire transmitters (Transmitter power supply: 24V DC) Output 11 to 5V, 4 to 20mA Output 21 to 5V, 4 to 20mA Response Time85ms max. |
- Isolated Signal Conditioner:Frequency Converters:Frequency/Analog Converter
-
MS3900 SeriesMS3908
Chassis Mount Type
Frequency/Analog Converter
Converts pulse train signals from flow sensors and the like into commonly used DC signals. |
35,000Yen |
6Days
|
7Years |
-
RoHS10
|
InputOpen collector, DC voltage pulse, current pulse, and others Output 11 to 5V, 0 to 5V, 0 to 10V, +/-5V, +/-10V Output 21 to 5V, 0 to 5V, 0 to 10V, +/-5V, +/-10V, 4 to 20mA Response TimeDependent on input frequency. |
- Isolated Signal Conditioner:Frequency Converters:Pulse Shapers (Pulse Isolators)
-
MS3900 SeriesMS3909
Chassis Mount Type
Pulse Shaper (Pulse Isolator)
Accepts pulse train signals from sensors or other devices and shapes these pulses or converts signal levels as necessary. |
35,000Yen |
6Days
|
7Years |
-
RoHS10
|
InputOpen collector, DC voltage pulse, current pulse, and others Output 1TTL, open collector Output 2TTL, open collector Response TimeDependent on input frequency. |
- Isolated Signal Conditioner:Sensor Signal Conditioners:Potentiometer Transmitters
-
MS3900 SeriesMS3910
Chassis Mount Type
Potentiometer Transmitter
Detects changes in the resistance of potentiometric sensors and converts them into commonly used DC signals. |
30,000Yen |
6Days
|
7Years |
-
RoHS10
|
InputBetween 0-100Ω and 0-10kΩ Output 11 to 5V, 0 to 5V, 0 to 10V Output 21 to 5V, 0 to 5V, 0 to 10V, 4 to 20mA Response Time170ms max. |
- Isolated Signal Conditioner:Sensor Signal Conditioners:PT Transmitters
-
MS3900 SeriesMS3921
Chassis Mount Type
PT Transmitter (Rms Calculation)
Calculates the rms values of AC current signals from a PT and converts them into commonly used DC signals. |
33,000Yen |
6Days
|
7Years |
-
RoHS10
|
Input0 to 110V AC, 0 to 150V AC, 0 to 300V AC, and others Output 11 to 5V, 0 to 5V, 0 to 10V, +/-5V, +/-10V Output 21 to 5V, 0 to 5V, 0 to 10V, +/-5V, +/-10V, 4 to 20mA Response Time400ms max. |
- Isolated Signal Conditioner:High-level Signal Conditioners:High-level Signal Conditioners (Isolators)
-
MS3900 SeriesMS3944
Chassis Mount Type
High-Level Signal Conditioner (Fast Response Model)
Converts DC current or voltage signals into pulse train signals. Ultra-fast response: 40kHz-3dB |
30,000Yen |
6Days
|
7Years |
-
RoHS10
|
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 11 to 5V, 0 to 5V, 0 to 10V, +/-5V, +/-10V |
- Isolated Signal Conditioner:High-level Signal Conditioners:High-level Signal Output Modules
-
MS3900 SeriesMS3954
Chassis Mount Type
High-Level Signal Conditioner
Converts DC current or voltage signals into commonly used DC signals. |
20,000Yen |
6Days
|
7Years |
-
RoHS10
|
Input4 to 20mA, 1 to 5V, 0.4V to 2V, and others Output 14 to 20mA, 550Ω at maximum output for single output Response Time15ms max. |
- Isolated Signal Conditioner:High-level Signal Conditioners:High-level Signal Output Modules
-
MS3900 SeriesMS3954HI
Chassis Mount Type
High-Level Signal Conditioner (High Current Load Model)
Converts DC current or voltage signals into commonly used DC signals. |
20,000Yen |
6Days
|
7Years |
-
RoHS10
|
Input4 to 20mA, 1 to 5V, 0.4V to 2V, and others Output 14 to 20mA, 550Ω at maximum output for single output Response Time15ms max. |
- Isolated Signal Conditioner:Chassis:Chassis for MS3900
-
MS3900 SeriesRC3900A-16AI
Chassis Mount Type
Rack
Chassis for the MS3900 series signal conditioners |
35,000Yen / 50,000Yen |
6Days
|
7Years |
CE
RoHS10
|
InputOutput 1 |
- Isolated Signal Conditioner:Chassis:Chassis for MS3900
-
MS3900 SeriesRC3900A-16AO
Chassis Mount Type
Rack
Chassis for the MS3954 signal conditioners |
35,000Yen / 50,000Yen |
6Days
|
7Years |
-
RoHS10
|
InputOutput 1 |
- Overview
- Download
- Price
- Standard Lead Time
- Warranty Period
- Standards & Approvals / RoHS
- Power Supply
- Details
- Basic Information
- Compare