MS3700 SeriesMS3701
Plug-in Type
Thermocouple Temperature Transmitter
Plug-in Type
Thermocouple Temperature Transmitter
Converts thermocouple inputs into commonly used DC signals. |
47,000Yen / 57,000Yen |
4Days
|
7Years |
CE
RoHS10
|
InputThermocouple types: K, E, J, T, B, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time160ms max. |
Plug-in Type
Fast-Response Thermocouple Temperature Transmitter
Converts thermocouple inputs into commonly used DC signals. This model features a fast response time of 500μs or less (0 to 90%). |
55,000Yen / 65,000Yen |
4Days
|
7Years |
-
RoHS10
|
InputThermocouple types: K, E, J, T, B, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time50μs max. |
Plug-in Type
RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
45,000Yen / 55,000Yen |
4Days
|
7Years |
CE
RoHS10
|
InputRTD: Pt 100Ω, JPt 100Ω, Ni 508.4Ω, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time170ms max. |
Plug-in Type
4-Wire RTD Temperature Transmitter
Converts 4-wire RTD inputs into commonly used DC signals. |
55,000Yen / 65,000Yen |
4Days
|
7Years |
-
RoHS10
|
Input4-wire RTD: Pt 100Ω, JPt 100Ω, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time170ms max. |
Plug-in Type
RTD Temperature Transmitter (for Narrow Temperature Spans)
Converts RTD inputs into commonly used DC signals. This model is intended for measurement of narrow temperature spans (e.g. Pt100Ω input span of 30 to 50°C) |
55,000Yen / 66,000Yen |
4Days
|
7Years |
-
RoHS10
|
Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time240ms max. |
Plug-in Type
RTD Differential Temperature Transmitter
Detects a temperature difference between two 2-wire RTD's and converts it into commonly used DC signals. |
64,000Yen / 74,000Yen |
4Days
|
7Years |
-
RoHS10
|
Input2-wire RTD: x2 Pt100Ω, JPt100, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time200ms max. |
Plug-in Type
RTD Differential Temperature Transmitter
Detects a temperature difference between two 2-wire RTD's and converts it into commonly used DC signals. |
74,000Yen / 84,000Yen |
4Days
|
7Years |
-
RoHS10
|
Input2-wire RTD: Pt100Ω -20 to 30°C, 0 to 50°C, 50 to 100°C, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time150ms max. |
Plug-in Type
Thermocouple Temperature Transmitter
Converts thermocouple inputs into commonly used DC signals. |
97,000Yen |
4Days
|
7Years |
-
RoHS10
|
InputThermocouple types: K, E, J, T, B, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V,, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time160ms max. |
Plug-in Type
RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
89,000Yen |
4Days
|
7Years |
-
RoHS10
|
InputRTD: Pt 100Ω, JPt 100Ω, Ni 508.4Ω, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time170ms max. |
Plug-in Type
Thermocouple Temperature Transmitter
Converts thermocouple inputs into commonly used DC signals. |
42,000Yen |
4Days
|
7Years |
-
RoHS10
|
InputThermocouple types: K, E, J, T, B, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time160ms max. |
Plug-in Type
RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
38,000Yen |
4Days
|
7Years |
-
RoHS10
|
InputRTD: Pt 100Ω, JPt 100Ω, Ni 508.4Ω, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time170ms max. |
Plug-in Type
Thermocouple Temperature Transmitter
Converts thermocouple inputs into commonly used DC signals. |
|
|
14Days
|
1Years |
-
-
|
InputThermocouple types: K、E、J、T、B、R、S、T、PL=Ⅱ、W5Re/W26Re、W3Re・W25Re Output 14~20mA 1~5V Response Time500ms max. |
Plug-in Type
Thermocouple Temperature Transmitter
Converts thermocouple inputs into commonly used DC signals. |
|
|
14Days
|
1Years |
-
-
|
InputThermocouple types: K、E、J、T、B、R、S、T、PL=Ⅱ、W5Re/W26Re、W3Re・W25Re Output 14~20mA 1~5V Output 24~20mA 1~5V Response Time500ms max. |
Plug-in Type
RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
|
|
14Days
|
1Years |
-
-
|
InputPt 100Ω、JPt 100Ω Output 14~20mA 1~5V Response Time500ms max. |
Plug-in Type
RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
|
|
14Days
|
1Years |
-
-
|
InputPt 100Ω、JPt 100Ω Output 14~20mA 1~5V Output 24~20mA 1~5V Response Time500ms max. |
Plug-in Type
RTD Differential Temperature Transmitter
Detects a temperature difference between two 2-wire RTD's and converts it into commonly used DC signals. |
|
|
14Days
|
1Years |
-
-
|
InputPt 100Ω、JPt 100Ω Output 14~20mA 1~5V Response Time500ms max. |
Terminal Block Type
Thermocouple Temperature Transmitter
Converts thermocouple inputs into commonly used DC signals. |
30,000Yen |
5Days
|
7Years |
CE*
* Except 12V DC RoHS10
|
InputThermocouple types: K, E, J, T, B, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time160ms max. |
Terminal Block Type
RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
29,000Yen |
5Days
|
7Years |
CE*
* Except 12V DC RoHS10
|
InputRTD: Pt 100Ω, JPt 100Ω, Ni 508.4Ω, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time170ms max. |
Terminal Block Type
Thermocouple Temperature Transmitter
Converts thermocouple inputs into commonly used DC signals. |
35,000Yen |
5Days
|
7Years |
CE
RoHS10
|
InputThermocouple types: K, E, J, T, B, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time160ms max. |
Terminal Block Type
RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
34,000Yen |
5Days
|
7Years |
CE
RoHS10
|
InputRTD: Pt 100Ω, JPt 100Ω, Ni 508.4Ω, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time170ms max. |
Chassis Mount Type
Thermocouple Temperature Transmitter
Converts thermocouple inputs into commonly used DC signals. |
35,000Yen |
6Days
|
7Years |
CE*
* Some variants are not CE compliant. RoHS10
|
InputThermocouple types: K, E, J, T, B, and others Output 11 to 5V, 0 to 5V, 0 to 10V, +/-5V, +/-10V, 4 to 20mA Output 21 to 5V, 0 to 5V, 0 to 10V, +/-5V, +/-10V, 4 to 20mA Response Time160ms max. |
Chassis Mount Type
RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
30,000Yen |
6Days
|
7Years |
CE*
* Some variants are not CE compliant. RoHS10
|
InputRTD: Pt 100Ω, JPt 100Ω, Ni 508.4Ω, and others Output 11 to 5V, 0 to 5V, 0 to 10V, +/-5V, +/-10V, 4 to 20mA Output 21 to 5V, 0 to 5V, 0 to 10V, +/-5V, +/-10V, 4 to 20mA Response Time170ms max. |
Unit Type
Thermocouple Temperature Transmitter
Converts thermocouple inputs into commonly used DC signals. |
30,000Yen |
Please contact us
|
7Years |
-
RoHS10
|
InputThermocouple types: K, E, J, T, B, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time160ms max. |
Unit Type
RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
30,000Yen |
Please contact us
|
7Years |
-
RoHS10
|
InputRTD: Pt 100Ω, JPt 100Ω, Ni 508.4Ω, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time170ms max. |
Chassis Mount Type
Thermocouple Temperature Transmitter
Converts thermocouple inputs into commonly used DC signals. |
35,000Yen |
6Days
|
3Years |
-
-
|
InputThermocouple types: K, E, J, T, B, and others Output 11 to 5V, 0 to 5V, 0 to 10V Output 21 to 5V, 0 to 5V, 0 to 10V, 4 to 20mA Response TimeApprox. 2Hz-3dB |
Chassis Mount Type
RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
30,000Yen |
6Days
|
3Years |
-
-
|
InputRTD: Pt 100Ω, JPt 100Ω, Ni 508.4Ω, and others Output 11 to 5V, 0 to 5V, 0 to 10V Output 21 to 5V, 0 to 5V, 0 to 10V, 4 to 20mA Response TimeApprox. 2Hz-3dB |
Chassis Mount Type
Thermocouple Temperature Transmitter
Converts thermocouple inputs into commonly used DC signals. |
|
35,000Yen |
14Days
|
7Years |
-
RoHS10
|
InputThermocouple types: K, E, J, T, B, and others Output 11~5V Response Time200ms max. |
Chassis Mount Type
Thermocouple Temperature Transmitter
Converts thermocouple inputs into commonly used DC signals. |
|
35,000Yen |
14Days
|
7Years |
-
RoHS10
|
InputThermocouple types: K, E, J, T, B, and others Output 11~5V Response Time200ms max. |
Chassis Mount Type
RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
|
30,000Yen |
14Days
|
7Years |
-
RoHS10
|
InputRTD: Pt 100Ω, JPt 100Ω, Ni 508.4Ω, and others Output 11~5V Response Time200ms max. |
Rack Mount Type
Thermocouple Temperature Transmitter
Accepts millivolt signals from a thermocouple, performs cold junction compensation, amplification and linearization, and provides two mutually isolated DC output signals. Successor model: MS3701 or MS4101 |
|
49,000Yen / 69,000Yen |
45Days
|
3Years |
-
-
|
InputThermocouple types: K, E, J, T, B, and others Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Output 21 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |