MS3700 SeriesMS3700DV
Plug-in Type
Voltage Divider
Plug-in Type
Voltage Divider
Converts high DC voltage signals into DC voltage signals. |
10,000Yen |
4Days
|
7Years |
-
RoHS10
|
Input+/-600V max. Output 1Value obtained by multiplying input voltage by division ratio |
Plug-in Type
Thermocouple Temperature Transmitter
Converts thermocouple inputs into commonly used DC signals. |
47,000Yen / 57,000Yen |
4Days
|
7Years |
CE
RoHS10
|
InputThermocouple types: K, E, J, T, B, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time160ms max. |
Plug-in Type
Fast-Response Thermocouple Temperature Transmitter
Converts thermocouple inputs into commonly used DC signals. This model features a fast response time of 500μs or less (0 to 90%). |
55,000Yen / 65,000Yen |
4Days
|
7Years |
-
RoHS10
|
InputThermocouple types: K, E, J, T, B, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time50μs max. |
Plug-in Type
RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
45,000Yen / 55,000Yen |
4Days
|
7Years |
CE
RoHS10
|
InputRTD: Pt 100Ω, JPt 100Ω, Ni 508.4Ω, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time170ms max. |
Plug-in Type
4-Wire RTD Temperature Transmitter
Converts 4-wire RTD inputs into commonly used DC signals. |
55,000Yen / 65,000Yen |
4Days
|
7Years |
-
RoHS10
|
Input4-wire RTD: Pt 100Ω, JPt 100Ω, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time170ms max. |
Plug-in Type
RTD Temperature Transmitter (for Narrow Temperature Spans)
Converts RTD inputs into commonly used DC signals. This model is intended for measurement of narrow temperature spans (e.g. Pt100Ω input span of 30 to 50°C) |
55,000Yen / 66,000Yen |
4Days
|
7Years |
-
RoHS10
|
Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time240ms max. |
Plug-in Type
Millivolt Isolator
Converts millivolt signals from sensors or other devices into commonly used DC signals. |
35,000Yen / 45,000Yen |
4Days
|
7Years |
CE
RoHS10
|
Input0 to 10mV, 0 to 100mV, +/-10V, +/-10mV, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time160ms max. |
Plug-in Type
High-Level Signal Conditioner (Isolator)
Converts DC current or voltage signals into commonly used DC signals. |
32,000Yen / 42,000Yen |
4Days
|
7Years |
CE
RoHS10
|
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time85ms max. |
Plug-in Type
High-Level Signal Conditioner (11-27V DC Powered)
Converts DC current or voltage signals into commonly used DC signals. This model operates with 11 to 27V DC power supply. |
42,000Yen / 52,000Yen |
4Days
|
7Years |
-
RoHS10
|
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time85ms max. |
Plug-in Type
High-Level Signal Conditioner (High Output Load Model)
Converts DC current or voltage signals into commonly used DC signals. This model features connection of output load resistance up to 1KΩ. |
42,000Yen |
4Days
|
7Years |
-
RoHS10
|
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 14 to 20mA, 0 to 20mA Response Time85ms max. |
Plug-in Type
Isolator (I/O Limited)
Converts 1 to 5V or 4 to 20mA DC signals into isolated 1 to 5V or 4 to 20mA DC signals. |
28,000Yen |
4Days
|
7Years |
CE
RoHS10
|
Input4 to 20mA, 1 to 5V Output 14 to 20mA, 1 to 5V Output 2Response Time85ms max. |
Plug-in Type
High-Level Signal Conditioner (24V AC Powered)
Converts DC current or voltage signals into commonly used DC signals. This model operates with 24V AC power supply. |
42,000Yen / 52,000Yen |
4Days
|
7Years |
-
RoHS10
|
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time85ms max. |
Plug-in Type
High-Level Signal Conditioner (I/O Switch-Selectable)
Built-in switches enable selection of input and output from either 1 to 5V or 4 to 20mA. |
50,000Yen |
4Days
|
7Years |
CE
RoHS10
|
Input4 to 20mA, 1 to 5V Output 14 to 20mA, 1 to 5V Output 24 to 20mA, 1 to 5V Response Time85ms max. |
Plug-in Type
High-Level Signal Conditioner (Outputs 1&2 Separately Adjustable)
Converts DC current or voltage signals into commonly used DC signals. This model features separate adjustment of Output 1 and Output 2. |
48,000Yen |
4Days
|
7Years |
-
RoHS10
|
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time85ms max. |
Plug-in Type
Alarm Setter with Isolated Dual Output
Compares the levels of DC current or voltage signals with two set-points (upper and lower limits) and outputs two independent isolated relay contact closure signals. |
55,000Yen |
4Days
|
7Years |
CE
RoHS10
|
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 1Two form C relay contact outputs Output 2Rated load of contact: 5A 125V AC, 5A 30V DC Response Time150ms max. |
Plug-in Type
Digital Alarm Setter (High Accuracy Model)
Compares the levels of DC current or voltage signals with two set-points (upper and lower limits) and outputs two independent isolated relay contact closure signals. |
60,000Yen |
4Days
|
7Years |
-
RoHS10
|
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 1Two form C relay contact outputs Output 2Rated load of contact: 5A 125V AC, 5A 30V DC Response Time150ms max. |
Plug-in Type
Digital Alarm Setter (High Accuracy Model)
Compares the levels of DC current or voltage signals with two set-points (upper and lower limits) and outputs two independent isolated relay contact closure signals. |
60,000Yen |
4Days
|
7Years |
-
RoHS10
|
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 1Two form C relay contact outputs; rated load of contact: 5A 125V AC, 5A 30V DC Output 2Two form C contact relay outputs; rated load of contact: 5A 125V AC, 5A 30V DC Response Time150ms max. |
Plug-in Type
Strain Gauge Transmitter
Supplies excitation voltage to strain-gauge type pressure sensors, load cells and the like and converts their output signals into commonly used DC signals. |
60,000Yen / 70,000Yen |
4Days
|
7Years |
-
RoHS10
|
InputSpan: 5 to 400mV; input range: -200 to 200mV; excitation voltage: 5V DC, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time85ms max. |
Plug-in Type
Strain Gauge Transmitter
Supplies excitation voltage to strain-gauge type pressure sensors, load cells and the like and converts their output signals into commonly used DC signals. |
70,000Yen / 80,000Yen |
4Days
|
7Years |
-
RoHS10
|
InputSpan: 0.8 to 10mV; input range: -5 to 5mV; excitation voltage: 5V, 10V DC Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time85ms max. |
Plug-in Type
Distributor (with Isolation)
Powers a two-wire transmitter and converts its 4 to 20mA signals into commonly used DC signals. This model can also be used as an isolator. |
38,000Yen / 48,000Yen |
4Days
|
7Years |
CE
RoHS10
|
Input4 to 20mA from 2-wire transmitters (Transmitter power supply: 24V DC) Output 14 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others Response Time85ms max. |
Plug-in Type
Distributor for Level Gauges
A wide span adjustment range allows the module to be used for level gauges with different ranges. |
55,000Yen / 65,000Yen |
4Days
|
7Years |
-
RoHS10
|
Input4 to 20mA from 2-wire transmitters (Transmitter power supply: 24V DC) Output 14 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others Response Time200ms max. |
Plug-in Type
Distributor with HART Communication
Powers a two-wire transmitter and converts its 4 to 20mA signals into 4 to 20mA signals. The module isolates bidirectional HART communication signals. |
45,000Yen |
4Days
|
7Years |
-
RoHS10
|
Input4 to 20mA from 2-wire transmitters (Transmitter power supply: 24V DC) Output 14 to 20mA Response Time500ms max. |
Plug-in Type
Frequency/Analog Converter
Converts pulse train signals from flow sensors and the like into commonly used DC signals. |
48,000Yen / 58,000Yen |
4Days
|
7Years |
-
RoHS10
|
InputOpen collector, DC voltage pulse, current pulse, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response TimeDependent on input frequency. |
Plug-in Type
Pulse Shaper (Pulse Isolator)
Accepts pulse train signals from sensors or other devices and shapes these pulses or converts signal levels as necessary. |
30,000Yen / 40,000Yen |
4Days
|
7Years |
-
RoHS10
|
InputOpen collector, DC voltage pulse, current pulse, and others Output 1TTL level, open collector, voltage pulse Output 2TTL level, open collector, voltage pulse Response TimeDependent on input frequency. |
Plug-in Type
Potentiometer Transmitter
Detects changes in the resistance of potentiometric sensors and converts them into commonly used DC signals. |
40,000Yen / 50,000Yen |
4Days
|
7Years |
CE
RoHS10
|
InputBetween 0-100Ω and 0-10kΩ Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time170ms max. |
Plug-in Type
4-Wire Potentiometer Transmitter
Detects changes in the resistance of four-wire potentiometers and converts them into commonly used DC signals. |
47,000Yen / 57,000Yen |
4Days
|
7Years |
-
RoHS10
|
Input4-wire potetiometer total resistance: 300Ω; input span: 50 to 200Ω Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time170ms max. |
Plug-in Type
Potentiometer Transmitter (Constant Current Model)
Detects changes in the resistance of potentiometric sensors and converts them into commonly used DC signals. This model features providing constant current to the sensor. |
47,000Yen / 57,000Yen |
4Days
|
7Years |
-
RoHS10
|
InputBetween 0-100Ω and 0-10kΩ Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time170ms max. |
Plug-in Type
Pulse Divider
Accepts pulse train signals from sensors or other devices, shapes or divides these pulses, and converts signal levels as necessary. |
50,000Yen / 60,000Yen |
4Days
|
7Years |
-
RoHS10
|
InputOpen collector, DC voltage pulse, current pulse, and others Output 1TTL level, open collector, voltage pulse Output 2TTL level, open collector, voltage pulse Response TimeDependent on input frequency. |
Plug-in Type
Pulse Divider
Accepts pulse train signals from sensors or other devices, shapes or divides these pulses, and converts signal levels as necessary. |
60,000Yen / 70,000Yen |
4Days
|
7Years |
-
RoHS10
|
InputDry contact, open collector, voltage pulse, current pulse, and others Output 1TTL level, open collector, voltage pulse Output 2TTL level, open collector, voltage pulse Response TimeDependent on input frequency. |
Plug-in Type
Square-Root Extractor
Extracts the square roots of DC current or voltage signals and converts them into commonly used DC signals. |
43,000Yen / 53,000Yen |
4Days
|
7Years |
-
RoHS10
|
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time120ms max. |